294 research outputs found

    Mechanical CPR devices

    Get PDF
    It is recognized that the quality of cardiopulmonary resuscitation (CPR) is an important predictor of outcome from cardiac arrest. Mechanical chest-compression devices provide an alternative to manual CPR. Physiological and animal data suggest that mechanical chest-compression devices are more effective than manual CPR. Consequently, there has been much interest in the development of new techniques and devices to improve the efficacy of CPR. This review will consider the evidence and current indications for the use of some of the more common mechanical devices developed to increase the safety and efficacy of CPR administration

    Accuracy of prediction of infarct-related arrhythmic circuits from image-based models reconstructed from low and high resolution MRI.

    Get PDF
    Identification of optimal ablation sites in hearts with infarct-related ventricular tachycardia (VT) remains difficult to achieve with the current catheter-based mapping techniques. Limitations arise from the ambiguities in determining the reentrant pathways location(s). The goal of this study was to develop experimentally validated, individualized computer models of infarcted swine hearts, reconstructed from high-resolution ex-vivo MRI and to examine the accuracy of the reentrant circuit location prediction when models of the same hearts are instead reconstructed from low clinical-resolution MRI scans. To achieve this goal, we utilized retrospective data obtained from four pigs ~10 weeks post infarction that underwent VT induction via programmed stimulation and epicardial activation mapping via a multielectrode epicardial sock. After the experiment, high-resolution ex-vivo MRI with late gadolinium enhancement was acquired. The Hi-res images were downsampled into two lower resolutions (Med-res and Low-res) in order to replicate image quality obtainable in the clinic. The images were segmented and models were reconstructed from the three image stacks for each pig heart. VT induction similar to what was performed in the experiment was simulated. Results of the reconstructions showed that the geometry of the ventricles including the infarct could be accurately obtained from Med-res and Low-res images. Simulation results demonstrated that induced VTs in the Med-res and Low-res models were located close to those in Hi-res models. Importantly, all models, regardless of image resolution, accurately predicted the VT morphology and circuit location induced in the experiment. These results demonstrate that MRI-based computer models of hearts with ischemic cardiomyopathy could provide a unique opportunity to predict and analyze VT resulting for from specific infarct architecture, and thus may assist in clinical decisions to identify and ablate the reentrant circuit(s)

    Cardiovascular magnetic resonance guided electrophysiology studies

    Get PDF
    Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such as atrial fibrillation and ventricular tachycardia are associated with suboptimal success rates and prolonged radiation exposure. Pre-procedure 3D CMR has improved understanding of the anatomic basis of complex arrhythmias and is being used for planning and guidance of ablation procedures. A particular strength of CMR compared to other imaging modalities is the ability to visualize ablation lesions. Post-procedure CMR is now being applied to assess ablation lesion location and permanence with the goal of indentifying factors leading to procedure success and failure. In the future, intra-procedure real-time CMR, together with the ability to image complex 3-D arrhythmogenic anatomy and target additional ablation to regions of incomplete lesion formation, may allow for more successful treatment of even complex arrhythmias without exposure to ionizing radiation. Development of clinical grade CMR compatible electrophysiology devices is required to transition intra-procedure CMR from pre-clinical studies to more routine use in patients

    Submillimeter diffusion tensor imaging and late gadolinium enhancement cardiovascular magnetic resonance of chronic myocardial infarction.

    Get PDF
    BackgroundKnowledge of the three-dimensional (3D) infarct structure and fiber orientation remodeling is essential for complete understanding of infarct pathophysiology and post-infarction electromechanical functioning of the heart. Accurate imaging of infarct microstructure necessitates imaging techniques that produce high image spatial resolution and high signal-to-noise ratio (SNR). The aim of this study is to provide detailed reconstruction of 3D chronic infarcts in order to characterize the infarct microstructural remodeling in porcine and human hearts.MethodsWe employed a customized diffusion tensor imaging (DTI) technique in conjunction with late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) on a 3T clinical scanner to image, at submillimeter resolution, myofiber orientation and scar structure in eight chronically infarcted porcine hearts ex vivo. Systematic quantification of local microstructure was performed and the chronic infarct remodeling was characterized at different levels of wall thickness and scar transmurality. Further, a human heart with myocardial infarction was imaged using the same DTI sequence.ResultsThe SNR of non-diffusion-weighted images was >100 in the infarcted and control hearts. Mean diffusivity and fractional anisotropy (FA) demonstrated a 43% increase, and a 35% decrease respectively, inside the scar tissue. Despite this, the majority of the scar showed anisotropic structure with FA higher than an isotropic liquid. The analysis revealed that the primary eigenvector orientation at the infarcted wall on average followed the pattern of original fiber orientation (imbrication angle mean: 1.96 ± 11.03° vs. 0.84 ± 1.47°, p = 0.61, and inclination angle range: 111.0 ± 10.7° vs. 112.5 ± 6.8°, p = 0.61, infarcted/control wall), but at a higher transmural gradient of inclination angle that increased with scar transmurality (r = 0.36) and the inverse of wall thickness (r = 0.59). Further, the infarcted wall exhibited a significant increase in both the proportion of left-handed epicardial eigenvectors, and in the angle incoherency. The infarcted human heart demonstrated preservation of primary eigenvector orientation at the thinned region of infarct, consistent with the findings in the porcine hearts.ConclusionsThe application of high-resolution DTI and LGE-CMR revealed the detailed organization of anisotropic infarct structure at a chronic state. This information enhances our understanding of chronic post-infarction remodeling in large animal and human hearts

    3D Determination of Area-at-Risk in Acute Myocardial Infarction

    Get PDF
    MRI methods for acute myocardial infarctio

    Algorithm for Mobile Platform-Based Real-Time QRS Detection

    Get PDF
    Recent advancements in smart, wearable technologies have allowed the detection of various medical conditions. In particular, continuous collection and real-time analysis of electrocardiogram data have enabled the early identification of pathologic cardiac rhythms. Various algorithms to assess cardiac rhythms have been developed, but these utilize excessive computational power. Therefore, adoption to mobile platforms requires more computationally efficient algorithms that do not sacrifice correctness. This study presents a modified QRS detection algorithm, the AccYouRate Modified Pan–Tompkins (AMPT), which is a simplified version of the well-established Pan–Tompkins algorithm. Using archived ECG data from a variety of publicly available datasets, relative to the Pan–Tompkins, the AMPT algorithm demonstrated improved computational efficiency by 5–20×, while also universally enhancing correctness, both of which favor translation to a mobile platform for continuous, real-time QRS detection

    Diminished Left Ventricular Dyssynchrony and Impact of Resynchronization in Failing Hearts With Right Versus Left Bundle Branch Block

    Get PDF
    ObjectivesWe compared mechanical dyssynchrony and the impact of cardiac resynchronization therapy (CRT) in failing hearts with a pure right (RBBB) versus left bundle branch block (LBBB).BackgroundCardiac resynchronization therapy is effective for treating failing hearts with conduction delay and discoordinate contraction. Most data pertain to LBBB delays. With RBBB, the lateral wall contracts early so that biventricular (BiV) pre-excitation may not be needed. Furthermore, the magnitude of dyssynchrony and impact of CRT in pure RBBB versus LBBB remains largely unknown.MethodsDogs with tachypacing-induced heart failure combined with right or left bundle branch radiofrequency ablation were studied. Basal dyssynchrony and effects of single and BiV CRT on left ventricular (LV) function were assessed by pressure-volume catheter and tagged magnetic resonance imaging, respectively.ResultsLeft bundle branch block and RBBB induced similar QRS widening, and LV function (ejection fraction, maximum time derivative of LV pressure [dP/dtmax]) was similarly depressed in failing hearts with both conduction delays. Despite this, mechanical dyssynchrony was less in RBBB (circumferential uniformity ratio estimate [CURE] index: 0.80 ± 0.03 vs. 0.58 ± 0.09 for LBBB, p < 0.04; CURE 0→1 is dyssynchronous→synchronous). Cardiac resynchronization therapy had correspondingly less effect on hearts with RBBB than those with LBBB (i.e., 5.5 ± 1.1% vs. 29.5 ± 5.0% increase in dP/dtmax, p < 0.005), despite similar baselines. Furthermore, right ventricular-only pacing enhanced function and synchrony in RBBB as well or better than did BiV, whereas LV-only pacing worsened function.ConclusionsLess mechanical dyssynchrony is induced by RBBB than LBBB in failing hearts, and the corresponding impact of CRT on the former is reduced. Right ventricular-only pacing may be equally efficacious as BiV CRT in hearts with pure right bundle branch conduction delay

    Acute Embolic Occlusion of the Left Common Iliac Artery Treated With Intra-Arterial Thrombolysis and Percutaneous Thrombectomy

    Get PDF
    Acute embolic occlusion of the common iliac artery is a rare medical emergency that is not only limb-threatening, but also potentially life-threatening. Several treatment options exist for acute limb ischemia, although no treatment is clearly best. We report a case of acute embolic occlusion of the left common iliac artery in a patient with atrial fibrillation who was treated successfully using mechanical thrombectomy following intra-arterial thrombolysis
    • …
    corecore